(100-Pair) P310 PORTA SYSTEMS STUBLESS CENTRAL OFFICE TERMINAL CONNECTOR BLOCKS
$ 355.47
- Description
- Size Guide
Description
MAKE OFFER!(100-Pair) P310 PORTA SYSTEMS TERMINAL CONNECTOR BLOCKS-STUBLESS CENTRAL OFFICE
The P310 is a 100-pair protector/connector block that utilizes wire-wrap terminations and industry standard 5-pin protector modules arranged in two 5x10 arrays. The P310 protects personnel and expensive equipment from damaging electrical surges that may get onto incoming cable lines. The unit has a compact design with straight or angled mounting options. Custom swivel stub permits field changes between stub up and down.
Auction is for (1) unit. 42 units available. These units are NOT wired, they come stubless.
MAKE OFFER!
SPECIFICATIONS
Operating Temperature-13 ̊F to 149 ̊F (-25 ̊C to 65 ̊C)
Meets or exceeds specifications Listed to UL 497 and those set forth in Telcordia GR-2916 and Telcordia TA-EOP-000164
Dimensions (height x width x depth) 9.3” x 3.5” x 10” (23.7 cm x 8.9 cm x 25.4 cm)
The P310 is a 100-pair protector/connector block that utilizes wire-wrap terminations and industry standard 5-pin protector modules arranged in two 5x10 arrays. The P310 protects personnel and expensive equipment from damaging electrical surges that may get onto incoming cable lines. The unit has a compact design with straight or angled mounting options. Custom swivel stub permits field changes between stub up and down.
CPE, Premise Wiring, Headend, CO Utility, Municipality,
For use on central office or distribution frames
Accepts industry standard 5-Pin protector modules
Compact, lightweight design saves space and increases number of protected pairs per frame vertical
Gold plated protector module sockets and test field contacts for superior electrical contact eliminating noise problems.
Fanning strips allow easy wire management for both field stubbing and cross connection to horizontal blocks
100-pair front-facing test field
Front ground test point offers labor savings and reliability
Custom connectorization available
Compatable-Commscope Systimax, Circa, Emerson Marconi, Tii Network Technologies tiitech.com: 26100-ST-MST, 190A1-100, 1900A1-100, 25100-110-M110C, 1880ENA1/NSC-100, BEPNCT100T, 25100-66-M66C, 1890ECT1/NSC-100, BEPNCC100C, 25100-ST-M110C, 489ACC1-100, 1880B1-100, BEPT100SC25, 25100-ST-M66C, 489BCC1-100, 1890BC1-100, BEPC100SC25, 26100-ST-MST, 190A1-100, 1900A1-100, R13410012, 24100-110-M110C, 489ACA1-100, 1880ECA1-100, BEPT100T, 24100-66-M66C, 489BCB1-100, 1890ECT1-100, BEPC100C, QCM486
COMMUNICATIONS BACKBONE CABLING271300-1SECTION 271300-COMMUNICATIONS BACKBONE CABLINGPART 1 -GENERAL1.1RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division01 Specification Sections, apply to this Section. B. BICSI Telecommunications Distribution Methods Manual (TDMM), Eleventh Edition.1.2SUMMARYA.Section Includes:1.Pathways.2.UTP cable.3.Cable connecting hardware, patch panels, and cross-connects.4.Cabling identification products. B. Related Sections:1.Section280513 "Conductors and Cables for Electronic Safety and Security" for voice and data cabling associated with system panels and devices. 1. 3DEFINITIONSA.BICSI: A professional association supporting the information technology systems (ITS) industry. B. Cross-Connect: A facility enabling the termination of cable elements and their interconnection or cross-connection. C. EMI: Electromagnetic interference. D. IDC: Insulation displacement connector. E. LAN: Local area network. F. RCDD: Registered Communications Distribution Designer. G. UTP: Unshielded twisted pair. protector modules Blocks Frame Central Office 100 Pair Stubless 100 Pair Wire-Wrap Connector Block
COMMUNICATIONS BACKBONE CABLING271300-21.4BACKBONE CABLING DESCRIPTIONA. Backbone cabling system shall provide interconnections between communications equipment rooms, main terminal space, and entrance facilities in the telecommunications cabling system structure. Cabling system consists of backbone cables, intermediate and main cross-connects, mechanical terminations, and patch cords or jumpers used for backbone-to-backbone cross-connection. B. Backbone cabling cross-connects may be located in communications equipment rooms or at entrance facilities. Bridged taps and splitters shall not be used as part of backbone cabling.
OUTSIDE TELEPHONE FEEDER CABLEA. Outside telephone feeder cable shall be a multi-twisted pair copper cable, gel filled, with coated aluminum shield and outer plastic jacket suitable for underground service. The cable shall have the following characteristics:1.Cable shall meet Rural Utilities Services (RUS) Specification PE-89.2.Conductors shall be solid, 24 gauge, annealed copper. Strands shall be individually insulated, polyethylene insulated cable (PIC) and twisted into pairs.3.Number of pairs in cable shall be noted for each job.4.Individual conductors shall be color coded per telephone industry practice.5.A petroleum gel shall be used to fill all voids and indices to prevent the intrusion of moisture.6. A coated aluminum shield shall encase the cable and be flooded with petroleum jelly. The shield shall be continuous throughout the length of the cable.7.The cable shall have an overall PVC jacket/sheath. The jacket/sheath shall be abrasion resistant, impervious to light or water.
COMMUNICATIONS BACKBONE CABLING271300-7A.Building Entrance Protectors1.All building protectors shall be AVAYA 489-Type or Circa 189 Type (or 4486 Type where specified) protection systems. Project will be responsible for matching protector types in existing buildings (P310-Type where specified). Pair count will be specified on a per job basis. Building protectors shall be STUB IN and STUBOUT type. Building protectors must conform to UL 497 Specifications.a.P310 is the type of protectors used in the FREY Building and in David Boyd Hall.1)Porta Systems Products by tii Network Technologies. 2)Part number is P310-WW-24-XX (where XX is length of cable stub in feet)3)Or approved equal. B. Building Protector Modules1.Protector modules shall be Avaya Type 3B1EW or Circa C3B1E gas tube with sneak protection. They shall be interchangeable 5-pin plug-in modules.